• PRODUCTS

- // PRODUCT DETAILS // -


Application

This standard applies of tree wire and messenger supported spacer cable and CCX etc. These conductors are intended primarily for the distribution of electrical energy under normal conditions of overhead (aerial) installations. They are considered as covered conductors therefore the cables carry no voltage rating. The conductors must be installed on insulators and/or spacers adequate for the service voltage. The user may want to give consideration to the dielectric compatibility of the covering, insulator, spacer and tree wire.

Description

The conductors are stranded,circular compressed aluminum, aluminum-alloy, copper, ACSR or ACSR/AW etc. The conductor screen is the extruded Semi-conducting conductor shield in Black. The inner Insulation is mainly natural color thermoplastic polyethylene (PE) or cross-linked polyethylene (XLPE). And the outer Insulation is mainly thermoplastic polyethylene (PE) or cross-linked polyethylene (XLPE) in Black or Grey or Red with Weather or UV resistant. This standard covers both thermoplastic and cross linked polyethylene constructions, rated for 75°C or 90°C normal service temperature.

Specifications

● ANSI/ICEA S-121-733 Tree Wire and Messenger Supported Spacer Cable
● NTC 5909 Cables De Potencia Cubiertos(Semiaislados) No Apantallados De 15000 Voltios-46000 Voltios,Para Uso En Lineas Aéreas De Distribución De Energía Eléctrica
● BS EN 50397-1 Covered Conductors for Overhead Lines and the Related Accessories for Rated Voltages above 1 kV a.c. and Not Exceeding 36 kV a.c.— Part 1: Covered conductors

15kV Tree Wire :
15kV Tree Wire
Size
(AWG or kcmil)
No.
of Wires
Covering ThicknessCable DiameterRated
Strength
Weight
Conductor ShieldInner LayerOuter Layer
No.mmmmmmmmkNkg/km
3-Layer 15kV ACSR/XLPE/HDPE
66/10.381.911.9113.65.28188
46/10.381.911.9114.88.30238
36/10.381.911.9115.610.2271
26/10.381.911.9116.512.7313
16/10.381.911.9117.415.6362
1/06/10.381.911.9118.519.4424
2/06/10.381.911.9119.623.3496
3/06/10.381.911.9120.729.4584
4/06/10.381.911.9122.437.1699
266.818/10.381.911.9123.730.3713
336.418/10.381.911.9125.238.2847
Size
( kcmil)
Number
of Wires
Covering ThicknessCable DiameterRated
Strength
Weight
Conductor ShieldInner LayerOuter Layer
No.mmmmmmmmkNkg/km
3-Layer 15kV AAAC/XLPE/HDPE
48.6970.381.911.9115.27.83223
77.4770.381.911.9116.812.4286
123.370.381.911.9119.018.9383
155.470.381.911.9120.123.8443
195.770.381.911.9121.530.0521
246.970.381.911.9123.037.8614
312.8190.381.911.9124.946.5740
394.5190.381.911.9127.458.6892
465.4190.381.911.9128.469.21008
559.5190.511.911.9130.483.11168
652.4190.511.911.9131.897.01320
740.8370.511.911.9133.31071463
Size
(AWG or kcmil)
No.
of Wires
Covering ThicknessCable DiameterRated
Strength
Weight
Conductor ShieldInner LayerOuter Layer
No.mmmmmmmmkNkg/km
3-Layer 15kV AAC/XLPE/HDPE
470.381.911.9114.43.52204
270.381.911.9115.85.39259
1/070.381.911.9117.77.96341
2/070.381.911.9118.69.99394
3/070.381.911.9119.712.15459
4/070.381.911.9121.115.30541
266.8190.381.911.9123.019.89648
336.4190.381.911.9124.924.57775
397.5190.381.911.9126.128.44878
477190.381.911.9127.933.301017
556.5370.511.911.9130.139.871161
636370.511.911.9131.545.361295
795370.512.032.0334.255.621557
25kV Tree Wire :
25kV Tree Wire
Size
(AWG or kcmil)
No.
of Wires
Covering ThicknessCable diameterRated
Strength
Weight
Conductor ShieldInner LayerOuter Layer
No.mmmmmmmmkNkg/km
3-Layer 25kV ACSR/XLPE/HDPE
1/06/10.383.183.1823.619.4586
2/06/10.383.183.1824.723.3666
3/06/10.383.183.1825.829.4763
4/06/10.383.183.1827.537.1891
266.818/10.383.183.1828.630.3913
336.418/10.383.183.1830.138.21058
Size
( kcmil)
No.
of Wires
Covering ThicknessCable DiameterRated
Strength
Weight
Conductor ShieldInner LayerOuter Layer
No.mmmmmmmmkNkg/km
3-Layer 25kV AAAC/XLPE/HDPE
48.6970.383.183.1820.17.83358
77.4770.383.183.1821.712.4434
123.370.383.183.1823.918.9547
155.470.383.183.1825.023.8616
195.770.383.183.1826.430.0704
246.970.383.183.1827.937.8809
312.8190.383.183.1829.646.5939
394.5190.383.183.1832.158.61109
465.4190.383.183.1833.169.21232
559.5190.513.183.1835.183.11407
652.4190.513.183.1836.597.01569
740.8370.513.183.1838.01071723
927.2370.513.183.1840.91352050
Size
(AWG or kcmil)
No.
of Wires
Covering ThicknessCable DiameterRated
Strength
Weight
Conductor ShieldInner LayerOuter Layer
No.mmmmmmmmkNkg/km
3-Layer 25kV AAC/XLPE/HDPE
1/070.383.183.1822.87.96497
2/070.383.183.1823.79.99556
3/070.383.183.1824.812.15630
4/070.383.183.1826.215.30723
266.8190.383.183.1827.719.89833
336.4190.383.183.1829.624.57973
397.5190.383.183.1830.828.441086
477190.383.183.1832.633.301237
556.5370.513.183.1834.839.871398
636370.513.183.1836.245.361542
795370.513.183.1838.955.621824
35kV Tree Wire :
35kV Tree Wire
Size
(AWG or kcmil)
No.
of Wires
Covering ThicknessCable DiameterRated
Strength
Weight
Conductor ShieldInner LayerOuter Layer
No.mmmmmmmmkNkg/km
3-Layer 35kV ACSR/XLPE/HDPE
1/06/10.384.453.1826.119.4682
2/06/10.384.453.1827.223.3767
3/06/10.384.453.1828.429.4868
4/06/10.384.453.1830.037.11002
266.818/10.384.453.1831.130.31028
336.418/10.384.453.1832.638.21179
Size
( kcmil)
No.
of Wires
Covering ThicknessCable DiameterRated
Strength
Weight
Conductor ShieldInner LayerOuter Layer
No.mmmmmmmmkNkg/km
3-Layer 35kV AAAC/XLPE/HDPE
48.6970.384.453.1822.67.83441
77.4770.384.453.1824.212.4523
123.370.384.453.1826.418.9644
155.470.384.453.1827.523.8718
195.770.384.453.1828.930.0811
246.970.384.453.1830.437.8922
312.8190.384.453.1832.146.51059
394.5190.384.453.1834.658.61238
465.4190.384.453.1835.669.21365
559.5190.514.453.1837.683.11547
652.4190.514.453.1839.097.01715
740.8370.514.453.1840.51071874
927.2370.514.453.1843.41352213
Size
(AWG or kcmil)
No.
of Wires
Covering ThicknessCable DiameterRated
Strength
Weight
Conductor ShieldInner LayerOuter Layer
No.mmmmmmmmkNkg/km
3-Layer 35kV AAC/XLPE/HDPE
1/070.384.453.1825.37.96590
2/070.384.453.1826.29.99653
3/070.384.453.1827.312.15731
4/070.384.453.1828.715.30829
266.8190.384.453.1830.219.89946
336.4190.384.453.1832.124.571094
397.5190.384.453.1833.328.441210
477190.384.453.1835.133.301369
556.5370.514.453.1837.339.871538
636370.514.453.1838.845.361688
795370.514.453.1841.455.621980
46kV Tree Wire :
46kV Tree Wire
Size
(kcmil)
No.
of Wires
Covering ThicknessCable DiameterRated
Strength
Weight
Conductor ShieldInner LayerOuter Layer
No.mmmmmmmmkNkg/km
3-Layer 46kV AAAC/XLPE/HDPE
48.6970.385.724.4527.77.83640
77.4770.385.724.4529.312.4734
123.370.385.724.4531.518.9873
155.470.385.724.4532.623.8955
195.770.385.724.4534.030.01060
246.970.385.724.4535.537.81182
312.8190.385.724.4537.246.51332
394.5190.385.724.4539.758.61531
465.4190.385.724.4540.769.21666
559.5190.515.724.4542.783.11864
652.4190.515.724.4544.197.02043
740.8370.515.724.4545.61072214
927.2370.515.724.4548.51352575
Size
(AWG or kcmil)
No.
of Wires
Covering ThicknessCable DiameterRated
Strength
Weight
Conductor ShieldInner LayerOuter Layer
No.mmmmmmmmkNkg/km
3-Layer 46kV AAC/XLPE/HDPE
1/070.385.724.4530.47.96810
2/070.385.724.4531.39.99880
3/070.385.724.4532.412.15968
4/070.385.724.4533.815.301077
266.8190.385.724.4535.319.891205
336.4190.385.724.4537.224.571367
397.5190.385.724.4538.428.441494
477190.385.724.4540.233.301666
556.5370.515.724.4542.439.871853
636370.515.724.4543.945.362014
795370.515.724.4546.555.622326

- // FORM MESSAGE // -