• PRODUCTS

2x3/0+1/0awg Aega Aluminum Conductor Triplex Overhead Service Drop Cable Wire

Triplex Service Drop Cable 3/0AWG Aega #3/0

Code Word: Aega

Size AWG (Phase Conductors): 3/0

Voltage: 600V

Number of cores: Triplex

Package : Export wooden drum & iron wooden drum or as customer require
Phone: +8613204662621
WhatsApp: +8613204662621
E-mail: yongbencable@163.com
Contact Us

- // PRODUCT DETAILS // -


3/0-3/0-1/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application


3/0-3/0-1/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable Wire has three conductors, with one of them being for neutral path, and two electrodes. The aluminum triplex cable is an electrical cable used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.


3/0-3/0-1/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard

• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts
CONSTRUCTION :

3/0-3/0-1/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger)Conductor

Bare ACSR messenger.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

TECHNICAL DATA :

3/0-3/0-1/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

V

600

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

PARAMETER :
3/0-3/0-1/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable Wire Parameter
Code NameAega
Phase Conductor Size/AWG3/0
Phase Conductor Stranding19/w
Phase Conductor Insulation Thickness60 mls
Bare Neutral Messenger Size/AWG1/0
Bare Neutral Messenger Stranding6/1
Bare Neutral Messenger Breaking Strength4380 Lbs
Weight Per (lb/1000 ft) XLP565 Lbs
Weight (lb/1000 ft) Poly552 Lbs
Ampacity XLP275 Amps
Ampacity Poly215 Amps

- // FORM MESSAGE // -

SEND

- // Related product recommendations // -