• PRODUCTS

2x4+6awg Strombus Aluminum Conductor Triplex Overhead Service Drop Cable Wire

Triplex Service Drop Cable 4AWG Strombus #4

Code Word: Strombus

Size AWG (Phase Conductors): 4

Voltage: 600V

Number of cores: Triplex

Package : Export wooden drum & iron wooden drum or as customer require
Phone: +8613204662621
WhatsApp: +8613204662621
E-mail: yongbencable@163.com
Contact Us

- // PRODUCT DETAILS // -


4-4-6 Strombus Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application


4-4-6 Strombus Triplex aluminum wire has three conductors, with one of them being for neutral path, and two electrodes. Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors. A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.

4-4-6 Strombus Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard

• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts
CONSTRUCTION :

4-4-6 Strombus Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger )Conductor

Bare ACSR messenger. Optional constructions include a messenger of AAC or 6201 alloy.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.



triplex-cable TECHNICAL DATA :

4-4-6 Strombus Aluminum Conductor Triplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

V

600

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

PARAMETER :

4-4-6 Strombus Aluminum Conductor Triplex Overhead Service Drop Cable Wire Parameter

 
Code NameStrombus
Phase Conductor MaterialAAC
Phase Conductor Size (awg)4
Phase Conductor Stranding7
Phase Conductor insulation MaterialXLPE
Phase Conductor Insulation Thickness (mils)45
Bare Neutral Messenger MaterialACSR
Bare Neutral Messenger Size(awg)4
Bare Neutral Messenger Stranding6/1
Bare Neutral Messenger Breaking Strength (Lbs)1190
Weight Per (Lbs/1000 ft) 160
Ampacity (Amps)115

- // FORM MESSAGE // -

SEND