• PRODUCTS

Copper Conductor Quadruplex Service Drop Cable 600V

Copper Conductor Quadruplex Service Drop Cable 600V

Conductor: Stranded compressed soft copper

Insulation: Thermoplastic Polyethylene or Cross-linked Polyethylene

Voltage: 600V

Number of cores: Quadruplex

Package: Export wooden drum & iron wooden drum or as customer require
Phone: +8613204662621
WhatsApp: +8613204662621
E-mail: yongbencable@163.com
Contact Us

- // PRODUCT DETAILS // -


Copper Quadruplex Service Drop Cable Application

Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. Also suitable for installations for street lighting, security lights, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors and 90 ºC for cross-linked polyethylene (XLP) insulated conductors.

Copper Quadruplex Service Drop Cable Specifications

Meets or exceeds the following ASTM specifications:
B-1 Hard-Drawn Copper Wire.
B-3 Soft or Annealed Copper Wire.
B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft.
Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and cross-linked polyethylene insulated conductors.

CONSTRUCTION :

Copper Quadruplex Overhead Service Drop Cable Wire Construction


Conductors are concentrically stranded compressed soft copper insulated with either cross-linked polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.

Notes:
Code words for XLP insulated products are formed by adding ""XLP"" to the conventional polyethylene code words above (e.g.-Theta/XLP).
Ampacity figures for black insulation only. Based on conductor temperature of 75 ºC for polyethylene insulated conductors, 90 ºC for XLP insulated conductors, ambient temperature of 40 ºC 2 ft./sec. wind in sun.
TECHNICAL DATA :

Copper Quadruplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

kV

0.6/1

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

PARAMETER :
Quadruplex Cable – Copper Service Drop Cable Wire Parameter
Code WordCopper Phase ConductorBare Copper Neutral MessengerWeight Per 1000 Ft. (lbs.)Allowable Ampacities+
Size (AWG)StrandingInsulation Thickness (mils.)Size (AWG)StrandingRated Strength (lbs.)PolyethyleneXLPPolyethyleneXLP
Atlanta67456Solid12803683747595
Tallahassee67456712283693767595
Richmond4745471938573581100125
Baton Rouge47454Solid1970570578100125
Jackson27452Solid3003889889135170
Seattle2745273050893893135170
Nashville1/019601/07475214201457180230
Lincoln2/019602/07592617731773205265
Raleigh3/019603/07736622202220235305
Denver4/019604/07915427812803270350

- // FORM MESSAGE // -